FaultCrate・GMC Yukon 2000–2006・Air conditioning or heater
Candidate cause (the documents say what to do)
HVAC blower motor resistor module / connector overheating
The terminal interface between the relay resistor module and its power connector may be unable to carry higher current for sustained blower operation.
Moisture and contaminants may enter the fresh air intake plenum and reach the module's circuit or corrode the terminals.
What to do
- Dealers install a new blower motor resistor and resistor module connector.
- Cut the wires back far enough to remove any melted insulation.
Caution: The connector must be replaced even if it was replaced in an earlier repair.
In the records
No record states work done for this cause.
See the evidence (1 technical documents, 3 records)
Passages of the technical documents
MODELS: 2003-2006 Chevrolet Avalanche, Suburban Tahoe 2003-2007 Chevrolet Silverado 2003-2006 GMC Yukon, Yukon XL 2003-2007 GMC Sierra Equipped with Manual HVAC (CJ3) or Heavy Duty Heater (C42)
General Motors (filed with NHTSA) 2012-01-01
the interface between the electrical terminals of the relay resistor module and the wiring connector that powers the module may be incapable of conducting higher current levels for sustained periods of blower motor operation.
General Motors (filed with NHTSA) 2012-01-01
In addition, moisture and other contaminants may enter the fresh air intake plenum and contact the internal circuit of the module or corrode the terminals.
General Motors (filed with NHTSA) 2012-01-01
If any of these were to occur, the relay resistor module or wiring connector could overheat and the HVAC blower may not function on certain blower settings or may be inoperative.
General Motors (filed with NHTSA) 2012-01-01
Records
- HVAC Blower Motor Resistor Module Overheating Recall 2011-02-21
- Blower resistor module corrosion from water entry into HVAC system Owner complaint 2016-08-22
- General Motors HVAC Blower Service Campaign Manufacturer communication 2011-06-27
A cause or a result a complaint states is the owner’s view or what a dealer told them, not an established fact.
Put together by FaultCrate from public records and technical documents. The cause and the repair are for the workshop to decide with the vehicle in front of it. Counts are records, not failure rates.